Insights · Whole face · Measurement

Morphological face height : bizygomatic width

Nasion-to-menton height divided by the widest facial width.

Confidence
Tier A · tight interval
Unit
ratio (dimensionless)
Landmarks
n, me, zy_R, zy_L
CI floor
± 0.03
dist(n, me) / dist(zy_R, zy_L)
Measure yours
Illustration · on your scan the same lines are drawn on your own photo

How to read it

Below the mean

the face is broad relative to its height for the reference group.

Near the mean

face height relative to width sits close to the reference mean.

Above the mean

the face is long relative to its width for the reference group.

Caveat

Bizygomatic width from a 2D photo carries a systematic ~3 mm bias versus direct caliper measurement (Lim 2022) and shifts with yaw. Treat the width term as approximate.

Reference values by population

Reference populationFemale (mean ± SD)Male (mean ± SD)nSource
North American White0.855 ± 0.0540.872 ± 0.0592326Farkas 1994/2005 (NA White young adults) prov.
East Asian0.809 ± 0.0550.828 ± 0.055618Farkas 2005 (Chinese/Japanese/Vietnamese/Thai pooled); Jayaratne 2012 (Southern Chinese, n=103) prov.
South Asian0.852 ± 0.0580.868 ± 0.06210Farkas 2005 (Indian); Metgudmath 2022 prov.
African / African diaspora0.856 ± 0.0580.871 ± 0.059300Farkas 2005 (African-American, Zulu, Angolan) prov.
Middle Eastern0.869 ± 0.0560.884 ± 0.06348Farkas 2005 (Turkish, Iranian, Egyptian); Al-Sebaei 2015 (Saudi, n=168) prov.
Hispanic / Latino0.832 ± 0.0560.843 ± 0.058120Farkas 2005 (Mexican-American) prov.
Not specified — show pooled0.845 ± 0.060.861 ± 0.0623922Unweighted pool of the six groups above prov.
Where these numbers come from

Transcribed from the cited anthropometric literature; SDs of ratios are propagated conservatively (independence assumed). Entries marked prov. await line-by-line audit against the primary tables — see the norm provenance note.

Why every value has an error bar

Every value Canthion reports carries a 1σ uncertainty propagated from MediaPipe Face Mesh's published accuracy (3.96% of inter-ocular distance mean absolute error per landmark, Kartynnik 2019). For a typical 300 px inter-pupil photo that is ≈12 px per landmark, which is why small ratios and angles get wide intervals. A number without an interval is a number pretending to be more precise than it is.

References
  • Farkas, Katic & Forrest (2005). International Anthropometric Study of Facial Morphology in Various Ethnic Groups/Races. J Craniofac Surg 16(4):615–646. doi.org/10.1097/01.SCS.0000171847.58031.9E
  • Lim, Abdul Shakor & Shaharudin (2022). Reliability and Accuracy of 2D Photogrammetry: A Comparison With Direct Measurement. Front Public Health 9:813058. doi.org/10.3389/fpubh.2021.813058

Related: how bone-level measurements are taken from a photo · methodology · all insights